Novotechnik Multi-Turn Rotary Sensors: MB1, MC1, MZ1 and RMB Compared

A multi-turn sensor knows how many revolutions it has made, and True-Power-On means it still knows after the power has been off — no battery, no gear train, no homing run.

A single-turn rotary sensor measures position within one revolution. Turn the shaft past 360 degrees and it starts again at zero. For a valve actuator or a throttle that is exactly right. For a crane hoist, a leadscrew, a winch or a steering column, it is useless — you need to know which revolution you are on.

That is what a multi-turn sensor provides, and the interesting question is how it remembers.

True-Power-On: why it matters

Traditional multi-turn designs count revolutions. That works while powered. Remove the power and the count has to be preserved somehow, which historically meant one of two compromises:

A battery, which keeps the counter alive. Batteries fail, and when one does the position is lost — usually discovered at the worst moment, and requiring a re-reference before the machine can move safely.

A mechanical gear train, which stores the turn count physically. No battery, but gears add size, backlash and a wear mechanism.

Novotechnik NOVOTURN technology takes a third route. The sensor determines absolute position across the full multi-turn range at power-up, without a battery and without a gear train. If the shaft is moved while the power is off — by hand, by gravity, by a load slipping — the sensor reports the true new position when it powers up, not the position it remembers.

For anything where an unexpected movement during a shutdown is possible, this is the difference between resuming safely and needing a manual re-reference.

The four series

MB1-3600 — absolute non-contacting multi-turn with True-Power-On NOVOTURN, in a 36.5 mm all-metal housing. The all-metal construction is the reason this one gets specified for rough duty. Available with CANopen and IO-Link.

MC1-2800 — NOVOTURN multi-turn with smart sensor functions, in a more compact 28 mm format. Also available with CANopen and IO-Link. The choice where space is constrained.

MZ1-2200 — NOVOTURN multi-turn with smart sensor functions in the smallest format of the three, 22 mm. CANopen available. For tight installations where an MC1 will not fit.

RMB-3600 — absolute non-contacting NOVOHALL multi-turn in a 36.5 mm all-metal housing, with analogue and digital interfaces and several versions available. NOVOHALL rather than NOVOTURN, so confirm the power-off behaviour against your requirement if the shaft can move during shutdown.

Smart sensor functions

The MC1 and MZ1 carry what Novotechnik describes as smart sensor functions. In practice this means parameters that would traditionally be fixed at manufacture — measuring range, zero point, direction of rotation, output scaling — can be configured rather than ordered.

Two consequences worth planning around. Commissioning gets faster, because the sensor is adjusted to the machine rather than the machine to the sensor. And spares holding gets simpler, because one configurable part can cover several positions that would otherwise need distinct part numbers.

If you hold spares across a fleet, ask about this specifically — it often reduces the number of variants you need to stock.

Choosing between them

  1. Start with the housing size. 36.5 mm, 28 mm or 22 mm. Mechanical space usually decides this before anything else does.
  2. Then the interface. CANopen across all three NOVOTURN series, IO-Link on MB1 and MC1, analogue and digital on RMB.
  3. Then robustness. The all-metal 36.5 mm housings of MB1 and RMB suit exposed and mobile applications.
  4. Then configurability. If you want smart sensor functions, MC1 or MZ1.

Where multi-turn is the right answer

  • Crane and hoist position — drum rotation over many turns, where the load position must be known immediately at power-up
  • Leadscrew and spindle position — linear motion driven through many revolutions
  • Winch and cable drums
  • Steering angle on mobile machinery, where lock to lock exceeds one turn
  • Multi-turn valve actuators — gate and globe valves that take many turns to stroke
  • Roll gap and screwdown adjustment in rolling mills

The common thread is that the mechanism travels through more than one revolution and the machine has to know where it is without a homing move.

When a single-turn sensor is enough

If total travel stays within one revolution, use a single-turn sensor — it is simpler and cheaper. The single-turn range covers that, including the RSC-2800 and RFC-4800.

Where a gearbox reduces a multi-turn mechanism to under one revolution at the measuring point, a single-turn sensor also works — but check the backlash, because it appears directly in your position reading.

Specifying

Send us the total number of revolutions, the resolution required, whether the shaft can move while the power is off, the interface your controller expects, the mechanical arrangement and available space, and the protection rating needed. Accent is the sole authorised Novotechnik distributor for India and SAARC.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Novotechnik Linear Position Transducers Compared: Which Series to Specify

The Novotechnik linear range spans four measurement technologies and a dozen mechanical formats. Three questions narrow it to one or two candidates in about a minute.

The Novotechnik linear position transducer range covers four distinct measurement technologies across more than a dozen mechanical formats. Approached as a catalogue it is bewildering. Approached as three questions it resolves quickly.

The questions are: how is it mounted, how long does it have to last, and does anything need to be inside a cylinder.

The four technologies

Potentiometric — a precision conductive plastic track with a wiper. Simple, absolute, direct DC output, no conditioning electronics, lowest installed cost. The wiper contacts the track, so there is a wear mechanism, though Novotechnik designs use a decoupled wiper tap and pendular fixed slide bearing specifically to give stick-slip-free movement and long life.

NOVOSTRICTIVE (magnetostrictive) — non-contacting. A magnet moves along a waveguide and position is derived from the timing of a returned pulse. No wear in the measuring path, long strokes available, and it can be built as a rod for installation inside a hydraulic cylinder.

NOVOPAD (inductive) — non-contacting inductive measurement in a compact profile. A wear-free alternative in a smaller package than magnetostrictive.

Integrated signal processing types — the TE1 family, which includes signal processing in the transducer and can be replaced without recalibration. That last property is worth noting for maintained plant: swapping the unit does not mean a commissioning exercise.

Question one: how does it mount

This narrows the field faster than anything else.

Rod style, actuated by a moving machine element

  • TEX rod type — potentiometric, pendular fixed slide bearing, decoupled wiper, long life
  • TX2 — potentiometric with a double-supported actuating rod, high adjustment speed. Available with pivot head mounting or mounting clamp.
  • LWH and LWG — potentiometric, the general-purpose workhorses of the range
  • LWX-003 and LWX-004 — the LWX-004 with a shaft-protected design for dirtier positions

Side actuated

  • TLH — potentiometric, side actuated, IP40 to IP54, rated from below minus 30 to above plus 100 degrees Celsius

Spring return, where the machine pushes but does not pull

  • TR and TRS with return spring, TEX with return spring, TE1 with return spring, LS1 with return spring

A return spring matters more than it sounds. If the actuating element only pushes the rod and relies on it following back, the spring is doing the measurement on the return stroke — and if it is absent or too weak for the speed, the reading lags.

Profile designs

  • TP1 — NOVOSTRICTIVE magnetostrictive in a robust profile, non-contacting
  • LS1 — NOVOPAD inductive, compact profile, double-sided supported actuating rod

Inside a hydraulic cylinder

  • TH1 — NOVOSTRICTIVE rod style, designed for integration into cylinders

Sensor kits for integration into your own housing

  • PTX — potentiometric sensor kit, for OEMs building the transducer into their own mechanics

Question two: how many cycles

This decides contacting against non-contacting.

For machine positioning, valve feedback, press setup and general industrial measurement at moderate cycle rates, potentiometric is entirely adequate and considerably cheaper installed. The objection people raise — that the wiper wears — is usually based on experience with wirewound potentiometers rather than conductive plastic elements with decoupled wipers.

For continuous high-cycle duty, for washdown environments, or where a failure is expensive enough that the wear mechanism is unacceptable in principle, specify NOVOSTRICTIVE or NOVOPAD. The cost difference buys the removal of the only wear path.

Question three: cylinder integration

If the measurement has to happen inside a hydraulic cylinder, the answer is TH1 and the other questions become secondary. A rod-style magnetostrictive transducer installed in a gun-drilled cylinder rod gives you position with nothing exposed to the outside world at all — no rod to be damaged, no seal to fail, no alignment to lose.

This is the right answer for mobile machinery, presses and any cylinder in a position where an external transducer would be destroyed.

Interfaces

Most of the range offers ratiometric or analogue output as standard. TH1, TP1 and TM1 also offer CANopen and IO-Link, which is worth knowing if the machine architecture is bus-based — see CANopen position sensors.

A quick way through

  1. Inside a cylinder? TH1.
  2. OEM integration into your own housing? PTX.
  3. High cycles, wet, or wear unacceptable? TP1 or LS1.
  4. Needs to be replaceable without recalibration? TE1.
  5. Everything else — LWH, TEX or TX2 depending on mounting, with a return spring variant if the actuator only pushes.

What to send us

Stroke length, mounting arrangement, whether the actuator pushes only or both ways, expected cycles per day, required accuracy as a number, output needed, protection rating, and temperature range. A sketch of the mechanical arrangement is worth more than any of them individually. Our note on selecting a linear position transducer covers the mechanical decisions in more depth.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Sensors for Packaging and Pharmaceutical Machinery

Packaging lines ask sensors to do the two things they are worst at: detect transparent material, and do it at high speed. Plus survive changeover and a validated cleaning regime.

Packaging and pharmaceutical machinery asks sensors to do the two things they find hardest — detect transparent and low-contrast material, and do it fast — while surviving frequent format changeovers and, in pharma, a cleaning regime with documentation attached.

Here is how the specification usually needs to go.

Transparent material is the defining problem

Clear film, PET bottles, glass vials, blister foil backing and cellophane overwrap are all close to invisible to a diffuse photoelectric sensor. The light passes through, very little comes back, and detection is marginal in a way that varies with ambient light and film tension.

The reliable answer is through-beam. Emitter and receiver facing each other, the target detected by beam interruption rather than reflection. Even a transparent object attenuates the beam measurably, and with sensitivity set correctly this is stable where diffuse sensing is not.

Where a through-beam arrangement is not mechanically possible, retro-reflective is second best, but expect to spend commissioning time on sensitivity and expect it to need revisiting when the film supplier changes. The D31C range covers all three modes in M18 and M30.

Speed, and what it means for switching frequency

A packaging line running 300 packs a minute gives a sensor 200 milliseconds per pack, and the detection window inside that is much shorter. Two things have to be fast enough: the sensor, and the controller reading it.

Switching frequency is a specification parameter that gets ignored on slow applications and becomes decisive here. If the sensor is counting, specify against the maximum line rate with margin, not the nominal rate.

The failure mode is characteristic: counts that are correct at low speed and drift low as the line speeds up. If you are seeing that, the sensor or the input scan rate is the cause, not the mechanism.

Small targets and tight geometry

Packaging machinery is compact. There is rarely room for an M30 body, and the targets — a tablet, a cap, a label edge — are small. This pushes towards M8 and M12 inductive bodies for metal targets, and towards photoelectric with a well-defined beam for everything else.

Where the target is small relative to the sensing field, the sensor may respond weakly or inconsistently. Specify the target size when you enquire; it changes the recommendation more than people expect.

Changeover survives or it does not

A line that changes format several times a week puts mechanical stress on everything adjustable. Sensors get knocked, brackets get moved and not moved back, and cables get caught.

Three things help:

  • Mount out of the changeover path wherever the geometry allows. The best protection is not being in the way.
  • Use positive mechanical location — a dowel or a machined seat rather than a slot — so a sensor that is removed goes back in exactly the same place.
  • Specify connector versions rather than fixed cable where sensors are routinely removed. An M12 connector survives repeated disconnection; a cable that is pulled through a machine frame every changeover does not.

Hygiene and cleaning in pharma

On pharmaceutical lines the cleaning regime is validated, which means it will not be adjusted to suit a sensor. Specify to survive it as it is.

  • Stainless steel bodies, flush mounting, no crevices, no exposed threads collecting product, no horizontal ledges.
  • Chemical compatibility with the actual cleaning agent — including the cable sheath, which is the component most often overlooked and quite often the first to degrade.
  • Rating against the wash, not the process. Where high-pressure hot washdown is used, see IP69K washdown specification. The connector matters as much as the sensor: an IP69K sensor on an IP65 connector is an IP65 installation.
  • Cable entries pointing down. Standing water on an upward-facing gland defeats any rating eventually.

Documentation

Pharmaceutical and export machinery frequently needs component documentation as part of the machine file — declarations of conformity, material certificates, and in some cases traceability to a production batch.

Establish what your quality system requires before ordering rather than during qualification. Components bought through unofficial channels are commonly untraceable, which is a difficult thing to discover late. Our note on buying direct versus through a channel covers how to avoid that.

Typical sensor map on a packaging line

  • Product presence and gap detection — through-beam photoelectric, dark-on
  • Counting — photoelectric with switching frequency specified against maximum line speed
  • Metal cap, can and foil detection — D30C inductive in M8 or M12
  • Carton, plastic and non-metal detection — capacitive, or photoelectric where the target moves fast
  • Guard and interlock positions — normally closed, so a cut cable stops the machine
  • Format part identification — inductive presence sensing to confirm the right tooling is fitted, which prevents an entire class of changeover error
  • Servo and axis position feedback — position measurement rather than switching; see the Novotechnik linear range

Specifying

Send us the target — material, size, whether it is transparent or reflective — the line speed in units per minute, the available mounting space, the cleaning regime, and the output your controller expects. For transparent targets, a sample or a photograph is worth more than a description.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Sensors for Cement Plants: Dust, Heat and Very Long Cable Runs

Cement dust is abrasive, conductive when damp, and gets absolutely everywhere. Combine that with kiln heat and 200 metre cable runs, and three ordinary specification choices become wrong.

Cement plants present a combination that is unusual even among heavy industries: extremely abrasive dust everywhere, intense radiant heat in one area, and cable runs long enough that the electrical specification changes.

Each of those individually is manageable. Together they invalidate a few habits that work fine elsewhere.

Dust is the dominant problem

Cement dust is abrasive, it is fine enough to penetrate anything imperfectly sealed, and when it takes up moisture it becomes conductive and mildly cementitious. That last property is the one that catches people out — dust that has been damp and dried is not dust any more, it is a thin layer of set material, and it does not brush off.

Three consequences for specification:

Optical sensing is difficult. Lenses foul fast. Where photoelectric sensing is unavoidable, use through-beam mode, specify substantially more range than the gap requires so there is margin to lose, and plan for cleaning access. Diffuse mode in a cement plant is rarely a good decision.

Capacitive sensing needs care. Damp dust on the sensing face reads as a target. Where capacitive sensing is genuinely needed, mount so the face cannot collect material.

Inductive sensing is the workhorse, because dust between the sensor and a metal target affects it very little. This is why most of what actually survives in a cement plant is inductive.

Long cable runs change the electrical specification

Cement plants are physically large. A sensor on a conveyor gallery may be 150 or 200 metres from the nearest panel, and at that distance two things that are normally irrelevant become decisive.

Voltage drop. Over a long run at small conductor size, the supply reaching the sensor is measurably lower than the supply leaving the panel. Check the sensor still has adequate supply voltage at the far end, and size the conductor accordingly.

Noise pickup. A long cable running alongside VFD output cabling is an efficient antenna. Cement plants are full of large drives, and VFD carrier frequencies couple readily into signal cables.

The practical answers: use screened cable and earth the screen at one end only, physically separate signal and drive cabling, and where an analogue measurement is involved prefer a current output over a voltage output — a 4 to 20 mA loop is immune to the voltage drop and far more tolerant of induced noise. For long-distance position measurement, a digital or fieldbus interface removes the problem entirely; see CANopen position sensors.

Kiln area heat

Near the kiln, kiln hood and clinker cooler, radiant heat rather than ambient temperature sets the case temperature. The remedies are the same as in any hot process: increase distance, fit a shield, or provide cooling — in that order of preference, because each step adds something that can fail.

Measure the case temperature at the intended mounting position during normal operation before ordering. It takes ten minutes and prevents a recurring replacement.

Applications through the plant

Conveyors

Belt drift, belt slip, underspeed and pull-cord status account for a large share of the sensor population in a cement plant. Speed and underspeed monitoring is a protection function — a stalled belt under load is a fire risk and a mechanical one.

Magnetic speed sensors from the D33C range are appropriate here, and they tolerate dust better than optical alternatives because they sense through non-ferrous material.

Bucket elevators

Speed monitoring and belt alignment. An elevator that slips or misaligns damages itself quickly, and the sensors that detect it are among the most valuable in the plant.

Chutes and transfer points

Blockage detection. This is where plugged-chute events become spillage events, and where a sensor that works is worth a great deal. The environment is as bad as it gets — material flow, impact, dust — so mount with standoff and protect mechanically.

Gates, dampers and diverter positions

Straightforward D30C inductive switching, specified with generous sensing distance so the standoff can absorb dust build-up and mechanical slop. Normally closed for anything safety-related.

Silo and hopper level

Point level detection at high and low. Where the vessel is metallic, external capacitive sensing is not available and the solution needs to be inside — which changes the technology choice. Tell us the vessel construction when you enquire, because it determines the answer.

Damper and valve position feedback

Where the control system needs actual position rather than open or closed, this is position measurement rather than proximity switching. Rotary sensors from the Novotechnik range cover it, with touchless variants for the dustier positions.

The specification habits worth adopting

  1. Bigger bodies, longer sensing distances, more standoff. M30 and above wherever space allows. The extra clearance is what tolerates dust build-up.
  2. Short-circuit protected outputs — the -3S suffix — on everything. Cable damage is routine over these distances.
  3. Screened cable, earthed one end, separated from drive cabling.
  4. Current or digital outputs for anything analogue over distance.
  5. Mount so faces shed material rather than collect it, and so they can be reached for cleaning.
  6. Standardise. A plant this size with forty variants cannot stock spares properly.

If you want help with the last one, send us the plant sensor list and we will map it to the smallest set of equivalents that covers it.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Sensors for Sugar Mills: Surviving Cane, Juice, Steam and the Season

A sugar mill runs flat out for six months and then stops. That season shape, not the humidity, is what should drive sensor specification — because there is no window to fix anything in February.

Sugar is an unusual industry to specify sensors for, because the operating pattern dominates everything else. A mill runs continuously through the crushing season and then stops for months. During the season, unplanned downtime is expensive and cane is waiting. Outside it, there is time to do anything.

That shape should drive the specification. The question is not what is adequate — it is what will run to the end of the season without attention, because there is no window to fix it in February.

What the environment actually does

Fibre gets everywhere. Cane fibre and bagasse work into every crevice, pack around sensor faces, and bridge gaps that were designed to stay open. On a capacitive sensor, packed fibre reads as a permanent target. On an optical sensor it blocks the lens.

Juice is sticky, and it sets. Sugar-bearing juice dries to a hard deposit. A sensor face that is wiped clean weekly stays fine; one that is not accumulates a coating that changes its behaviour gradually rather than suddenly, which makes the fault hard to attribute.

Steam and humidity are constant. The boiling house runs wet and warm. Thermal cycling between a hot process area and cooler night-time ambient drives moisture into anything imperfectly sealed.

Mill drives vibrate heavily. Cane mills are high-torque, low-speed and rough. Mountings loosen and cables chafe.

Where sensors go, and what to specify

Cane carrier and feed

Belt or chain movement, level in the feed chute, and blockage detection. The requirement here is standoff — the sensor must be far enough from the material stream that fibre does not pack against it, which means specifying a larger body with a longer sensing distance than the geometry strictly needs. An M30 with 15 mm sensing mounted at 10 mm will outlast an M12 with 4 mm mounted at 3 mm, every season.

D30C inductive switches in M30 and above are the standard choice for metal targets on carriers and drives.

Mill roller speed and direction

Underspeed detection on mill rollers is a protection function, not a monitoring nicety — a slipping or stalled roller needs to be detected before something breaks. Magnetic speed sensors from the D33C range handle this, and the speed-and-direction variants are useful where reverse rotation matters.

Note the 30 mA output rating on that series: it feeds a controller input, not a contactor coil directly.

Juice, syrup and molasses level

This is where capacitive sensing earns its place. Juice has a high dielectric constant and is detected easily, and where the vessel wall is non-metallic the sensor can be mounted externally with nothing wetted and nothing to clean.

The caution is specific to this industry: syrup and molasses cling. If product coats the inside of the wall, an externally mounted capacitive sensor reads full permanently. Assess that before committing to the approach — on thin juice it usually works well, on heavy molasses often not.

Centrifugal position and interlocks

Lid position, discharge plough position and safety interlocks. Specify normally closed for anything that is a guard or a safety interlock, so a severed cable produces the stopped state rather than the running one.

Bagasse handling and boiler feed

Conveyor movement, chute blockage and level. Dusty, fibrous and in places warm. Photoelectric sensing is possible but needs through-beam mode and generous range margin, because lenses foul quickly in bagasse dust. Where a mechanical or inductive solution exists, it will usually need less attention.

Boiling house and pan floor

Warm, wet and steamy. Specify for washdown conditions rather than for the nominal ambient, and point every cable entry downward. Our note on IP67, IP68 and IP69K covers what each rating actually tests.

Specify for the season, not the day

Three practical rules that follow from the operating pattern:

Over-specify the sensing distance. The extra standoff is what buys tolerance to fibre packing and deposit build-up. This is the single highest-return decision in a sugar mill.

Standardise the part numbers. A mill with forty sensor variants cannot hold meaningful spares of any of them. A mill with eight can. During the season, being able to substitute from stores in ten minutes is worth more than an optimal specification for each position.

Specify short-circuit protected outputs. The -3S suffix. In an environment with this much vibration and cable chafe, output shorts happen, and an unprotected sensor is destroyed by the first one.

Use the off-season properly

The maintenance window between seasons is the time to do the things that prevent in-season failures: replace sensors that were marginal rather than failed, re-route cables that are chafing, fit guard brackets where something got hit, and rationalise the spares holding.

If you want to do that rationalisation, send us the current sensor list from the plant — part numbers and positions — and we will map it to the smallest set of equivalents that covers the mill. It is a more useful exercise than replacing like for like, and the off-season is when there is time to act on it.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Proximity Sensors for Steel Plants and Rolling Mills: What Survives

In a rolling mill the sensor is rarely what fails first — the cable is. What heat, scale, descaling water and vibration each do to an installation, and how to specify around them.

A steel plant destroys sensors in a small number of very predictable ways. Once you know what they are, specification becomes a matter of designing around each one rather than hoping a high IP rating covers everything.

These are the five failure mechanisms we see, in roughly the order they cause problems.

1. Radiant heat, which is not the same as ambient temperature

The mistake is specifying against the plant ambient. A sensor mounted two metres from hot stock is not at ambient — it is receiving radiant heat continuously, and its case temperature can be far above the air around it.

Three responses, in order of preference:

  • Move it. Distance is the cheapest heat shield there is, and a mounting position half a metre further back often solves the problem permanently.
  • Shield it. A simple steel plate between the sensor and the radiating source blocks the line of sight. Effective and cheap.
  • Cool it. Air purge or water cooling where the first two are not possible. Reliable, but now you have a service that can fail.

Measure the actual case temperature at the intended position during normal production before ordering. It is a ten minute job and it prevents a recurring replacement.

2. Scale

Mill scale is conductive, magnetic and abrasive, and it accumulates on everything. On an inductive sensor face a scale build-up can trigger the sensor permanently, which presents as a sensor that is stuck on and gets replaced unnecessarily.

Mount sensors facing downward or vertically where possible so scale falls away rather than collecting. Where the face must point up, plan for cleaning access, because it will need it.

3. Descaling water and cooling water

High-pressure descaling spray is closer to an IP69K condition than an IP67 one, and it comes with thermal shock: a hot sensor hit by cold water contracts rapidly and draws water past marginal seals. See our note on IP67, IP68 and IP69K for what each rating actually tests.

Specify for the spray, and point cable entries downward. An upward-facing cable gland in a wet area collects standing water and fails eventually regardless of its rating.

4. Vibration and mechanical damage

Mills vibrate, and cobbles happen. Two consequences worth designing for:

Mountings loosen. A sensor that drifts out of position reads intermittently and gets blamed on electronics. Use locknuts on both sides, and check alignment as part of routine maintenance rather than after failure.

Things get hit. A sensor in an exposed position will eventually be struck by stock, by scale, or by a maintenance trolley. Where you cannot move it out of the way, a simple guard bracket costs very little and saves the sensor.

5. The cable, which is what usually actually fails

In our experience of mill installations, the sensor is rarely the first thing to go. The cable is — chafed on a sharp edge, crushed under something, cooked against a hot surface, or pulled out of the gland by thermal movement.

Specify the cable properly. Route it away from heat and away from sharp edges. Support it so the gland carries no weight. Leave a service loop. And where the run is long, consider specifying a made-to-length cable so the first joint is outside the hostile zone rather than inside it.

What to specify where

Position and limit sensing on cold or warm sections — D30C inductive switches, sized with generous sensing distance so the standoff can be increased for heat and scale clearance. M30 and above rather than M12 where space allows.

Hot stock detection and tracking — hot metal detectors, which sense radiated infrared and therefore need no proximity to the stock at all. Specification is a geometry problem; see what to specify before ordering an HMD.

Long-distance presence detection across a pass line — D31C photoelectric in through-beam mode, specified with substantially more range than the gap so there is margin as the lenses foul.

Roll and shaft speed, and direction — magnetic speed sensors from the D33C range, which detect through non-ferrous material and tolerate the environment better than optical encoders.

Screwdown, roll gap and hydraulic cylinder position — this is not proximity switching but absolute position measurement, and it wants a Novotechnik transducer. For high-cycle or wet positions the touchless rotary series are the appropriate choice.

Hazardous areas in the gas plant or by-products section — NAMUR switches with a suitable amplifier. See specifying intrinsically safe NAMUR loops.

Standardise the spares holding

A practical point that matters more than any individual specification. Mills accumulate sensor variety — a dozen manufacturers, forty part numbers, and a stores holding that cannot cover any of them properly.

Rationalising to a smaller number of variants across the plant reduces stockholding, makes substitution possible during a breakdown, and means the maintenance team knows the parts. If you want to do that exercise, send us the current sensor list and we will map it to the smallest set of equivalents that covers it.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Replacing Imported Proximity Switches: How to Cross-Reference Correctly

Cross-referencing a sensor on body size and sensing distance alone is how machines end up with parts that fit and do not work. The six parameters that must match, and the two people forget.

A sensor fails. The label says something from a European or Japanese manufacturer, the lead time is eight weeks, and someone suggests finding an Indian equivalent. That is usually a good idea. It goes wrong when the cross-reference is done on body size and sensing distance alone.

Those two parameters determine whether the part fits. Four more determine whether it works, and two others determine whether it keeps working. Here is the full list.

The parameters that must match

1. Body size and thread

M8, M12, M18, M30, M36, M50. Straightforward, but check thread length as well as diameter — a sensor with a shorter barrel may not reach through a thick bracket, and one with a longer barrel may bottom out.

2. Sensing distance, adjusted for the target

Match the nominal figure, then check what the target actually is. Catalogue sensing distances are quoted against standard mild steel. If the machine senses aluminium or stainless steel, the effective distance is shorter — and if the original sensor was specified with that already accounted for, a nominal match may not be a functional one.

Our note on reduction factors for different metals has the correction figures.

3. Shielded or unshielded

This is the one most often missed, and it fails in a specific and confusing way. A shielded sensor can be mounted flush in metal. An unshielded one senses further but needs a clear zone around the face.

Fit an unshielded sensor into a mounting designed for a shielded one and it triggers on the bracket, permanently. The symptom is a sensor that reads on with nothing in front of it, and it gets diagnosed as a faulty sensor about half the time. See shielded versus unshielded.

4. Output type — NPN or PNP

Must match the input card. A PNP sensor into an NPN input does nothing at all, which at least is obvious. The subtler failure is an input card that accepts both but was configured for one.

5. Contact function — NO or NC

Match the original unless you are deliberately changing the logic. Substituting NO for NC and fixing it in the PLC works, but it leaves a machine whose wiring no longer matches its drawings, and the next person will lose a morning to it.

6. Supply voltage and output current

Confirm the supply range covers what the panel provides, and that the output current rating exceeds what the load actually draws including inrush.

The two that get forgotten

Connection method

Cable or connector. If connector, which one — M12 four-pin is common but not universal, and pin assignment varies. If cable, what length? A replacement with a 2 metre tail where the original had 5 metres means a junction box that was not in the plan.

This is worth specifying rather than accepting, because a made-to-length cable is usually available and removes the problem entirely.

Switching frequency

Rarely checked, occasionally decisive. If the sensor is counting teeth on a rotating shaft or detecting parts on a fast line, the replacement must switch at least as fast as the original. A sensor that is perfectly adequate for a limit position will miss counts on a high-speed application.

If the application is counting or speed sensing, say so — it changes the recommendation, often towards the D33C range.

What to send us

The fastest cross-reference comes from three things:

  1. The full part number from the label, photographed rather than transcribed. Sensor labels use characters that are easy to misread, and a wrong digit sends the whole exercise sideways.
  2. A photograph of the sensor installed, showing the mounting and how close the surrounding metal is. This answers the shielded question, the thread length question and often the target question at once.
  3. What it is sensing, and at what distance.

If you have the machine wiring diagram, the page showing the sensor is more useful than the sensor datasheet.

What you get from switching

Replacing imported sensors with domestically manufactured equivalents changes three things that matter on a maintained asset.

Lead time becomes a production question. No ocean freight, no customs clearance in the critical path.

The part stays available. Imported ranges get rationalised, and distributors change. A part made in Mumbai is subject to neither.

Variants become possible. Cable length, connector type and housing details can be specified rather than accepted — which, on a machine where you are replacing a dozen sensors anyway, is a chance to remove the junction boxes that were only ever there because the standard cable was too short.

Where we would tell you not to switch

If the original is doing something an inductive, capacitive, photoelectric or magnetic switch cannot do — absolute linear or rotary position measurement, for example — then a proximity switch is not the equivalent, whatever the mounting suggests. In that case the right answer is a position transducer from the Novotechnik range, and we will say so rather than sell you the wrong category of device.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

How to Read an Accent Part Number: The Complete Ordering Code Guide

Every Accent part number encodes the whole specification. Once you can read it, you can write the exact part you need onto a requisition without opening a catalogue.

Every Accent sensor part number describes the complete specification of the product. Series, body size, sensing distance, output type, contact function, wiring and protection are all in there. Once the pattern is clear, you can read any part number off a label and write a replacement code without opening a catalogue.

This page is the decoder for the whole range.

The series prefix

The first four characters identify the technology:

  • D30C — DC inductive proximity switch, three-wire. The general-purpose range.
  • D31C — photoelectric switch.
  • D32C — capacitive proximity switch.
  • D33C — magnetic proximity switch, including speed and direction variants.
  • D20C — NAMUR inductive proximity switch, for intrinsically safe duty.
  • A20C — AC two-wire inductive proximity switch.

Inductive, capacitive and NAMUR: D30C, D32C, D20C, A20C

These follow a common pattern:

D30C-1204-NM-3S

D30C Series
12 Body thread in mm — 08, 12, 18, 30, 36 or 50
04 Nominal sensing distance in mm
N Output transistor — N for NPN, P for PNP
M Contact function — M for normally open (make), B for normally closed (break)
3S Three-wire, short-circuit protected. Plain 3 omits the protection.

So the body and sensing distance pair together as four digits. 1204 is M12 with 4 mm sensing. 5030 is M50 with 30 mm. 3015 is M30 with 15 mm.

A20C differs only in the output section, because an AC two-wire sensor has no transistor type. A20C-1808-M-2 is M18, 8 mm, normally open, two-wire.

D20C NAMUR parts carry the NA suffix instead of an output code, because a NAMUR sensor does not switch a load — it changes the current it draws. D20C-1805-NA is M18 with 5 mm sensing, NAMUR output.

Photoelectric: D31C

Photoelectric parts need two extra fields, because sensing mode and range are independent of body size.

D31C-18TB-15000-PL-2S

D31C Series
18 Body thread — 18 or 30
TB Sensing mode — TB through-beam, RR retro-reflective, DR diffuse reflective
15000 Sensing range in mm
P Output — P for PNP, N for NPN
L Logic — L for light-on, D for dark-on
2S Short-circuit protected

Magnetic and speed sensing: D33C

D33C-18MD-NM-3S is an M18 magnetic proximity switch, NPN normally open, three-wire, short-circuit protected, rated 30 mA.

An additional SD suffix indicates the speed and direction variant, used for rotation monitoring where the control system needs to know not just that a shaft is turning but which way. D33C-30MD-NM-3S-SD is the M30 version.

Note the output current: the D33C range is rated 30 mA rather than the 200 to 300 mA of the switching ranges. It is designed to feed a controller input, not to drive a contactor directly. Driving a relay coil from one is a common and avoidable mistake.

Output current by series

  • D30C — 200 mA and 300 mA depending on variant
  • D31C — 200 mA
  • D32C — 300 mA
  • D33C — 30 mA
  • A20C — 200 mA

Check the actual current your load draws. A contactor coil inrush can be several times its holding current, and a sensor sized on the holding figure will fail.

The suffixes that matter most

S for short-circuit protection. The difference between -3 and -3S. Small price difference, prevents the most common field failure. Specify it unless there is a reason not to.

M and B. Make and break — normally open and normally closed. Worth choosing deliberately rather than defaulting: on a safety-relevant interlock, normally closed means a cut cable produces the stopped state.

N and P. NPN and PNP. Determined by your input card, not preference. See PNP versus NPN sensors.

Reading a worn label

If the label on an installed sensor is partly illegible, you can usually reconstruct the code. Measure the thread to get the body size. Count the wires: two means A20C or D20C, three means one of the DC ranges. Trace the output to see whether it sources or sinks. Then send us what you have — a photograph of the sensor in place and its wiring is generally enough for us to identify the part.

Cross-referencing another manufacturer

If you are replacing a competitor part rather than an Accent one, send us the full part number from the label and the application. We will identify the equivalent rather than ask you to work through the decoder — see our guide to replacing imported proximity switches.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

A20C AC Two-Wire Proximity Switches: Retrofitting Panels With No DC Supply

Older Indian plant runs on AC contactor logic with no DC rail anywhere near the machine. The A20C exists for exactly that retrofit — and for the leakage current problem it creates.

A great deal of working plant in India was built around AC contactor logic. There is no 24 V DC rail, no PLC input card, and no convenient place to get one — just a contactor coil that needs switching and a mechanical limit switch that has finally worn out.

Replacing that limit switch with a modern DC three-wire proximity sensor means adding a power supply, finding panel space, and running a new circuit. The A20C exists so you do not have to.

What a two-wire AC sensor is

It wires exactly like a mechanical switch: in series with the load, two wires, no separate supply. The sensor takes its operating power through the load itself. When it switches, current flows to the contactor coil; when it does not, only a small residual current flows.

That makes it a genuine drop-in replacement for a limit switch, a reed switch or a microswitch, with no panel modification at all. For retrofit work on ageing plant this is frequently the difference between a half-hour job and a rewiring project.

The A20C range

Eight body and sensing combinations, each available normally open or normally closed:

  • M12 — 2 mm and 4 mm sensing
  • M18 — 5 mm and 8 mm
  • M30 — 10 mm and 15 mm
  • M36 — 20 mm
  • M50 — 30 mm

All are two-wire, rated 200 mA. The ordering code follows the house pattern:

A20C-1808-M-2 — M18 body, 8 mm sensing, normally open (M for make), two-wire. Substitute B for break to get the normally closed version.

The two things that catch people out

Two-wire AC sensors have two well-known characteristics. Neither is a fault, but both cause confusion when they are not expected.

Residual current. Because the sensor powers itself through the load, a small current flows even when the sensor is off. In most cases the contactor coil ignores it. With a very low-burden load — a solid-state relay input, an electronic timer, some PLC AC input cards — that residual current can be enough to hold the load partially on, or to make an input read permanently true.

The symptom is a contactor that hums, or an input that never clears. The fix is a bleeder resistor across the load to give the residual current somewhere to go. Check the minimum load current your device requires before ordering.

Voltage drop. The sensor drops a small voltage across itself when conducting, because it needs that to operate. With a single sensor this is immaterial. Put three in series for an interlock chain and the drops add, and the coil at the end may not see enough voltage to pull in reliably.

If you are chaining sensors, add up the drops and compare against the coil pull-in voltage. Where the sum is marginal, use DC sensors and a relay instead. Our note on series and parallel connection of proximity switches covers the arithmetic.

When to use AC two-wire, and when not to

Use it for direct replacement of a worn mechanical switch in an AC panel, where the load is a contactor or solenoid with a normal burden, and where you want to avoid adding a DC supply.

Do not use it where the load is electronic and low-burden, where several sensors must be chained in series, where fast switching is required, or where you are building new. On a new machine, specify DC three-wire from the D30C range — more output options, no residual current, no voltage drop, and better diagnostics.

Why this range still matters

Because a very large amount of Indian manufacturing capacity was installed before DC control became standard, and that plant still has to run. A machine from the 1990s with a failed limit switch does not need a control system upgrade. It needs a sensor that fits the wiring that is already there.

The A20C is made in Mumbai to IEC 60947-5-2, so obsolescence is not a concern in the way it is with an imported range that may be rationalised away.

Ordering

Send the body size the existing mounting takes, the sensing distance needed, whether the function is normally open or normally closed, the AC supply voltage, and what the sensor is switching — ideally with the coil rating. If you are replacing a mechanical switch, a photograph of the installation usually answers the mounting questions faster than measurements do.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Accent D31C Photoelectric Switches: Range, Sensing Modes and Ordering

Choosing between diffuse, retro-reflective and through-beam decides reliability more than any other parameter. The full D31C range, what each mode is good at, and how the ordering code works.

When the sensing distance you need is beyond what an inductive switch can reach, or the target is not metal, the answer is usually photoelectric. The D31C range covers that requirement with 72 variants in M18 and M30 bodies, and the single most important decision is not the model number — it is which of the three sensing modes you choose.

Get the mode right and a photoelectric sensor runs for years. Get it wrong and it becomes the device the maintenance team resents.

The three sensing modes

Through-beam puts the emitter and the receiver in separate housings, facing each other. The target is detected when it breaks the beam. This is the most reliable mode by a wide margin: the receiver sees a strong, direct signal, so dust, fog, mist and a dirty lens all have to degrade it a long way before detection fails. It is also the only mode that reliably detects shiny, dark, transparent and irregularly shaped objects, because it does not depend on anything being reflected back.

The cost is installation. Two housings, two mounting brackets, and cable to both sides.

Retro-reflective puts the emitter and receiver in one housing and a reflector opposite. The beam travels out, bounces off the reflector and returns. Detection occurs when the target interrupts it. You get most of the range of a through-beam arrangement with only one electrical connection to make — the reflector needs mounting but not wiring.

The limitation is shiny targets. A polished or reflective object can bounce enough light back to look like the reflector, and the sensor misses it.

Diffuse reflective puts everything in one housing with no reflector at all. The beam reflects off the target itself. Simplest to install, shortest range, and most sensitive to the target surface — a matt black object reflects very little and is detected at a fraction of the distance a white one is. Background objects within range can also trigger it.

The D31C range

Diffuse reflective

  • M18 — 100 mm and 300 mm
  • M30 — 500 mm, 1000 mm, 2500 mm and 3000 mm

Retro-reflective

  • M18 — 1000 mm, 2000 mm, 3000 mm and 5000 mm
  • M30 — 10000 mm, 15000 mm and 20000 mm

Through-beam

  • M18 — 1000 mm, 3000 mm, 5000 mm, 10000 mm and 15000 mm

Every variant is available in all four output combinations, three-wire, 200 mA, short-circuit protected.

Reading the ordering code

A typical part number:

D31C-18TB-15000-PL-2S

  • D31C — photoelectric switch series
  • 18 — M18 body (or 30 for M30)
  • TB — sensing mode: TB through-beam, RR retro-reflective, DR diffuse reflective
  • 15000 — sensing range in millimetres
  • P — output type: P for PNP, N for NPN
  • L — output logic: L for light-on, D for dark-on
  • 2S — short-circuit protected

So D31C-30RR-20000-ND-2S is an M30 retro-reflective unit with 20 metre range, NPN output, dark-on, short-circuit protected.

Light-on or dark-on

This catches people out because the intuitive answer is often the wrong one.

Light-on switches the output when the receiver sees light. Dark-on switches when it does not.

For a through-beam or retro-reflective sensor detecting an object passing through the beam, dark-on gives you an output when the object is present — which is usually what the control logic wants. For a diffuse sensor, light-on gives you an output when the object is present, because the object is what returns the light.

There is also a fail-safe consideration. With through-beam set to dark-on, a failed emitter, a cut cable or a power loss all produce the same state as object present. If that state stops the machine, the failure is safe. If it starts something, it is not. Think this through for the specific function rather than accepting the default.

Choosing the mode for your application

  • Transparent objects — through-beam, with sensitivity adjusted. Glass and clear film are close to invisible to diffuse sensors.
  • Shiny or polished metal — through-beam. Retro-reflective will miss it.
  • Dark or matt targets — through-beam or retro-reflective. Diffuse ranges collapse on dark surfaces.
  • Dusty environments — through-beam, and specify more range than the geometry needs so there is margin as the lenses foul.
  • Long distances — retro-reflective in M30 reaches 20 metres, the longest in the range.
  • Limited access on one side — retro-reflective or diffuse, since only one side needs wiring.
  • Short-range presence detection with easy access — diffuse, the simplest and cheapest to install.

Specifying with margin

The quoted range is measured under clean conditions with a standard target. In a working plant, lenses accumulate dust and reflectors get knocked. Specify a sensor whose rated range comfortably exceeds the actual distance, so there is headroom to lose before detection becomes marginal.

A 3 metre gap served by a 3 metre sensor will work at commissioning and become intermittent by the second monsoon. A 5 metre sensor on the same gap will not.

Ordering

Send us the distance, the target — material, colour, surface finish, size, whether it is transparent — the environment, whether both sides of the gap are accessible, and the output your controller expects. We will specify the mode and return the part number. Our photoelectric switch range is manufactured in Mumbai, and non-standard cable lengths are available on request.

If the distance is short and the target is metal, an inductive switch from the D30C range will usually be cheaper and more robust — worth checking before defaulting to photoelectric.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Accent D30C Inductive Proximity Switches: Full Range and Ordering Guide

The D30C is Accent core DC inductive range — M8 to M50, 4 mm to 30 mm sensing, 72 variants. Here is how the ordering code works so you can specify the exact part in one line.

The D30C is the range most Indian plants actually run on: a DC three-wire inductive proximity switch, made in Mumbai to IEC 60947-5-2, in every combination of body size, sensing distance and output that ordinary machine building needs.

There are 72 variants. That sounds like a lot until you understand the ordering code, at which point specifying the exact part you need becomes a single line. This guide explains the code and the four decisions behind it.

Reading the ordering code

A typical part number looks like this:

D30C-1204-NM-3S

It decodes as:

  • D30C — the series: DC inductive proximity switch
  • 12 — body thread, M12
  • 04 — nominal sensing distance, 4 mm
  • N — output transistor type: N for NPN, P for PNP
  • M — contact function: M for normally open (make), B for normally closed (break)
  • 3S — three-wire with short-circuit protection. Plain 3 is the same without protection.

So D30C-5030-PB-3S is an M50 body, 30 mm sensing, PNP, normally closed, three-wire, short-circuit protected. Once the pattern is clear you can write the part number straight onto a requisition.

Decision one: body size and sensing distance

These two are linked. A larger coil senses further, so body size and sensing distance move together across the range:

  • M8 — for tight mechanical spaces, shortest sensing distance
  • M12, 4 mm — the general-purpose small sensor
  • M18, 5 mm and 8 mm — the most widely used size in Indian plants
  • M30, 10 mm and 15 mm — where standoff matters or the target position is less well controlled
  • M36, 20 mm — heavy machinery, larger clearances
  • M50, 30 mm — maximum inductive sensing distance in the range

Two cautions on sensing distance. First, the quoted figure is the nominal distance against a standard mild steel target; the assured operating distance you should design to is shorter. Leave margin. Second, non-ferrous targets reduce the distance — stainless steel, aluminium, brass and copper each by a different factor. Our note on reduction factors for different metals gives the arithmetic. Specifying an M12 4 mm sensor for an aluminium target at 3.5 mm is a fault waiting to happen.

Decision two: NPN or PNP

This is determined by your input card, not by preference. PNP sources current into the input and is the general standard in Europe and increasingly in India. NPN sinks current and is common in Japanese and some Indian-built equipment.

Get it wrong and the sensor appears dead, or appears permanently on. If you are replacing an existing sensor, match what is already there unless you are also changing the input card. Our guide to PNP versus NPN explains how to tell which you have.

Decision three: normally open or normally closed

Normally open (M) is the default: the output switches on when a target is present. Normally closed (B) switches off when a target is present.

The reason to choose NC deliberately is fail-safe behaviour. On a guard interlock or an end-of-travel limit, a normally closed sensor means a broken cable produces the same signal as an unsafe condition, so the machine stops. With normally open, a broken cable looks identical to a healthy sensor with no target, and the machine keeps running. Where the consequence of a missed detection is significant, specify NC.

Decision four: short-circuit protection

The 3S variants include short-circuit protection on the output; the 3 variants do not. The price difference is small and the failure it prevents is common — a crushed cable or a wiring error that shorts the output destroys an unprotected sensor immediately.

Specify 3S unless you have a specific reason not to. The D30C range carries 200 mA and 300 mA output ratings depending on variant; check the load current your solenoid or relay actually draws rather than assuming.

Flush and non-flush mounting

One decision the code does not cover but that matters mechanically: whether the sensor is designed to be mounted flush in metal or must stand proud. Shielded sensors can be embedded in a metal bracket; unshielded sensors sense further but need a clear zone around the face. Mounting an unshielded sensor flush in steel makes it trigger on the bracket. Our note on shielded versus unshielded sensors covers the clearances.

The rest of the range

The D30C covers DC inductive switching. Adjacent needs are served by other series:

  • D32C capacitive — for plastic, liquid, powder, wood and glass
  • D20C NAMUR — for intrinsically safe and hazardous-area duty
  • D31C photoelectric — where the sensing distance exceeds inductive range
  • A20C AC two-wire — for retrofits into panels with no DC supply available
  • Magnetic switches — for sensing through non-ferrous walls

Ordering

If you know the code, send it. If not, send the target material, the sensing distance required, the body size your mounting allows, the output your input card expects, whether the function should be NO or NC, and the supply voltage. We will return the part number and price. Non-standard cable lengths and connector options are available on request — worth asking about on any order above a handful of pieces, because it usually removes a junction box from every machine.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

LVDT Manufacturers in India — and When a Potentiometric Transducer Is the Better Buy

Buyers search for LVDTs because that is the technology they know. For most industrial stroke measurement in India, a potentiometric or Hall-effect transducer is cheaper, more available and entirely adequate.

A lot of linear position enquiries in India arrive asking for an LVDT. Often the application genuinely needs one. Just as often the buyer is asking for an LVDT because that is the technology they encountered first, and a potentiometric or Hall-effect transducer would do the job for less money, with shorter lead times and easier support.

This is a comparison of the three technologies from a purchasing point of view rather than a physics one, so that the enquiry you send matches the problem you have.

LVDT: what it is genuinely good at

A linear variable differential transformer measures displacement through electromagnetic coupling between a primary coil and two secondary coils, with a movable core. Because the core does not touch the coils, there is no wear in the measuring path.

Its real strengths are narrow and worth respecting:

  • Very high resolution over short strokes. Sub-micron measurement is achievable. For metrology, materials testing and precision gauging, nothing else is as appropriate.
  • Effectively infinite mechanical life in the measuring path.
  • Excellent repeatability in a controlled environment.

The costs are equally specific. An LVDT needs AC excitation and signal conditioning electronics, so the installed cost is well above the sensor price. Strokes are typically short. And the whole assembly is more expensive than the alternatives by a margin that is difficult to justify unless you are actually using the resolution.

Potentiometric: the workhorse

A potentiometric transducer is a precision resistive track with a wiper. Apply a voltage across the track and the wiper delivers a voltage proportional to position. It is the simplest possible arrangement and it remains the correct answer for a large share of industrial stroke measurement.

  • Direct DC output with no conditioning electronics required
  • Absolute by nature — position is known at power-up with no homing
  • Long strokes available, well past what LVDTs practically cover
  • Substantially lower installed cost

The trade-off is the wiper. It is a contacting device, so in very high-cycle applications the track eventually wears. In practice, for machine positioning, hydraulic cylinder feedback, valve position and press ram measurement, this is rarely the limiting factor — and Novotechnik conductive plastic elements are considerably more durable than the wirewound potentiometers the objection usually has in mind.

The Novotechnik potentiometric range we supply covers a wide span of formats: TLH side-actuated, LWH, LWG and LWX, the TR and TRS spring-return units, TEX in rod and pivot-head mountings, TE1, TX2, and the PTX sensor kit for integration into a customer housing.

Hall-effect and touchless: the modern middle ground

Magnetic touchless transducers give you the wear-free measuring path of an LVDT without the excitation and conditioning overhead. There is no contact, the output can be a straightforward analogue signal or a digital bus, and protection ratings can be very high because nothing has to penetrate the housing.

For high-cycle industrial applications that do not need sub-micron resolution, this is frequently the correct modern answer, and it is where a lot of applications that would once have used an LVDT now sit.

Choosing between them

Specify an LVDT when you need sub-micron resolution over a short stroke, in metrology, materials testing or precision gauging — and when you have budgeted for the signal conditioning.

Specify potentiometric for general machine positioning, cylinder feedback, valve position and press applications, where you need a reliable absolute reading, a simple DC output and a sensible price. This covers most industrial enquiries.

Specify touchless when cycle counts are high, the environment is hostile, washdown is involved, or you want the position on a fieldbus.

On sourcing LVDTs in India specifically

Worth being direct: we do not manufacture LVDTs, and we would rather say so than sell you something adjacent and call it equivalent. What we do supply is the full Novotechnik linear position transducer range as sole authorised distributor for India and SAARC, covering potentiometric and touchless technologies across a wide range of strokes and mountings.

If your application genuinely requires an LVDT, tell us and we will say so. If it does not — and in our experience most do not — we can usually offer a transducer that is available faster, costs less installed, and needs no signal conditioning.

What to send us

  • Stroke length required, and the mechanical space available
  • Resolution and accuracy genuinely needed, as a number rather than as high
  • Expected cycles per day and the intended service life
  • Output required and the controller it feeds
  • Environment: temperature, protection rating, washdown, vibration
  • Mounting arrangement, and whether a return spring is needed

Our guide to selecting a linear position transducer covers the mechanical decisions in more detail.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

CANopen Position Sensors: Selection and Supply for Indian Machine Builders

Putting position on the bus removes an analogue input card, its wiring and a calibration step. Which Novotechnik series carry CANopen, what to confirm about profiles, and when analogue is still the better answer.

Machine builders standardising on CAN keep arriving at the same question: can we take position measurement onto the bus rather than running it as analogue into an input card? For most of the Novotechnik range the answer is yes, and the reasons to do it are more practical than they first appear.

What moving position onto CANopen actually saves

An input card and its wiring. Each analogue position signal needs a channel, a screened cable run and a termination. On a machine with six position measurements that is most of a card plus the loom.

The analogue conversion chain. A digital sensor reports position as a number. An analogue one reports a voltage or current that then has to be scaled, and every step in that chain contributes error and drift. Removing it removes a calibration task from commissioning and a drift mechanism from service.

Diagnostics. This is the benefit that justifies the change on its own. An analogue sensor reading mid-scale is indistinguishable from a healthy sensor at mid-position. A bus device reports its own status, so the controller knows the difference between a sensor saying halfway and a sensor that has stopped talking.

Commissioning time. Parameters set over the bus rather than by trimming.

Which series carry CANopen

From the Novotechnik range we distribute in India, CANopen is available on:

Rotary sensors

Linear transducers

Several of these also support IO-Link — MB1-3600, MC1-2800, TF1, TH1 and TP1 — which is worth knowing if your architecture uses IO-Link masters at the machine level rather than CAN throughout.

What to confirm before ordering

Fieldbus variants are configured to the protocol at manufacture. This is not a setting that can be changed on site, so the following need to be right at order stage.

  1. CANopen specifically, not CAN generally. CANopen, J1939 and proprietary CAN implementations all run on the same physical layer and do not interoperate. Confirm which one your controller actually speaks.
  2. The device profile. Encoder devices commonly follow CiA 406. Check your master expects that profile.
  3. Node ID and baud rate setting method. Whether these are set by hardware switch, by configuration over the bus, or fixed at order.
  4. Termination. Whether the sensor includes a terminating resistor or whether you supply it. A bus terminated twice, or not at all, is a classic commissioning fault.
  5. Redundancy. RFX-6900 and RSX-7900 offer redundant measurement channels. If the position feeds a safety function, specify this at the start.
  6. The EDS file. Ask for it with the quotation, not after delivery.

When analogue is still the right answer

Bus is not automatically better. Analogue remains sensible when you need one position signal rather than several, when the controller has a spare analogue input and no CAN master, when you are replacing a single sensor in an existing machine, or when the maintenance team is set up for analogue troubleshooting and not for bus diagnostics. Converting one sensor to CANopen on a machine that is otherwise entirely analogue adds complexity without collecting the benefit.

Where a mixed approach makes sense, several of these series are available in both analogue and bus variants, so the mechanical design can stay identical while the interface differs.

Ordering

Send us the measurement required — angle or stroke — the controller and CAN master you are using, the profile expected, the mechanical arrangement, the protection rating needed, and whether redundancy is required. Accent is the sole authorised Novotechnik distributor for India and SAARC, so configuration questions go back to the factory rather than being guessed at.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

IP69K Sensors for Washdown: Food, Dairy and Beverage Lines

IP67 and IP69K protect against completely different things, and a sensor can pass one while failing the other. What high-pressure washdown actually does to a sensor, and how to specify for it.

Sensors on food, dairy and beverage lines do not usually fail because of the process. They fail because of the cleaning.

A clean-down cycle can combine water at 80 bar and 80 degrees Celsius with a caustic or acidic detergent, applied at close range by someone whose priority is a clean machine rather than an intact sensor. It is a more aggressive environment than the production process it is protecting, and it defeats hardware specified for the process alone.

IP67 and IP69K protect against different things

This is the distinction that matters, and it is routinely missed because the numbers look sequential.

IP67 certifies protection against temporary immersion — the sensor can sit under water at low pressure for a defined period. It says nothing about pressure, nothing about temperature, and nothing about a directed jet.

IP69K certifies protection against close-range, high-pressure, high-temperature water jets. The test applies water at approximately 80 bar and around 80 degrees Celsius from a short distance, at several angles, while the item rotates.

These are genuinely different failure mechanisms. Immersion applies gentle uniform pressure. A high-pressure hot jet applies concentrated force at a seam, and heat at the same time. Heat causes the air inside a sealed housing to expand and then, as the jet passes and the surface cools rapidly, to contract — creating a partial vacuum that actively draws water past any seal that is less than perfect.

That thermal cycling is why washdown failures often appear weeks after installation rather than immediately, and why a sensor can pass an IP67 test and still fail in a dairy.

Neither rating covers the chemistry

IP ratings test with water. Clean-down uses detergents, and typically alternates caustic and acid cycles. Chemical compatibility is a separate question from ingress protection and needs asking separately.

The materials that matter are the housing, the sensing face, the cable sheath and the seals. Stainless steel housings are standard for good reason; the cable sheath is the component most often overlooked and quite often the first to degrade. If your CIP regime uses a specific detergent, name it when you enquire.

What else to specify beyond the rating

  • Hygienic mounting. Flush mounting with no crevices, no exposed threads collecting product, no horizontal ledges. In many plants this is an audit requirement, not a preference.
  • Cable entry orientation. The most common ingress path is a cable entry pointing upward, collecting standing water. Point it down, or specify a connector version.
  • The connector, if used. An IP69K sensor on an IP65 connector is an IP65 installation. The rating applies to the assembly, not the most impressive component in it.
  • Temperature range including the clean cycle. The process may run at 4 degrees and the wash at 80. Specify against the wash.
  • Cable length. A joint in the cable inside the wash zone is a failure point. Specify the full run to outside the zone.

What we supply for washdown duty

For position measurement in washdown environments, several Novotechnik series are rated to IP69 and are designed for exactly this kind of duty:

  • RFX-6900 — absolute touchless redundant NOVOHALL heavy duty rotary sensor, rated to IP67 and IP69 variants
  • RSX-7900 — absolute non-contacting redundant NOVOHALL heavy duty rotary sensor, also available to IP69
  • IPX-7900 — absolute high-precision potentiometric rotary sensor for harsh operating conditions, available to IP69

These are touchless or sealed designs with no mechanical path into the measuring element, which is the structural reason they survive washdown rather than merely being rated for it.

For proximity switching duty on washdown lines, tell us the clean-down regime — pressure, temperature, detergent and frequency — and we will confirm what we can supply against it. We manufacture inductive, capacitive and photoelectric switches in Mumbai and can advise on the right specification for the wash conditions you actually run, rather than the ones the catalogue assumes.

A note on over-specification

IP69K is not free, and not every sensor on a food line needs it. A sensor inside a control panel, or one mounted above the wash zone and never directly jetted, does not. Map the wash zone honestly and specify IP69K where the jet actually reaches. Spending the budget on the sensors that get hit, rather than spreading it across all of them, usually produces a more reliable line.

Our overview of IP67, IP68 and IP69K ratings explains what each test involves in more detail.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Capacitive Sensors for Plastic, Powder and Non-Metal Detection

An inductive switch cannot see plastic. Capacitive switches can, including through a container wall. How the D32C is specified, where it works, and the two mistakes that cause false triggering.

An inductive proximity switch sees metal and nothing else. That is not a limitation, it is the operating principle — it works by inducing eddy currents in a conductive target. Present it with a plastic bottle, a paper carton, a wooden pallet or a bin of powder and it will sit there indifferent.

Capacitive proximity switches solve that problem. They respond to a change in the dielectric in front of the sensing face, which means they detect essentially anything: plastic, liquid, powder, granulate, wood, glass, cardboard, and metal too.

How the sensing actually works

The sensing face forms one plate of a capacitor. The surroundings form the other. When a material enters the sensing field, the dielectric constant of the space in front of the face changes, the capacitance changes, and an internal oscillator circuit detects the shift and switches the output.

Two consequences follow, and they explain most of what is useful and most of what goes wrong.

Materials with a high dielectric constant are detected more easily. Water is detected extremely well. Metals behave as if they have an effectively infinite dielectric constant and are detected at the full rated distance. Dry plastics and powders have low dielectric constants and are detected at a reduced distance. This is why a sensor that detects a full bottle reliably may not detect an empty one.

The sensor cannot inherently distinguish target from contamination. A film of water, a dust build-up or a layer of product on the sensing face changes the dielectric just as a target does. This is the dominant failure mode in the field and it is a design problem rather than a device problem.

Sensing through a container wall

This is the application capacitive switches are genuinely unmatched at, and the one that brings most enquiries to us.

Mount the sensor on the outside of a non-metallic tank, hopper or pipe and set the sensitivity so that the wall alone does not trigger it but wall plus contents does. You then have a level switch with no penetration, no seal, no wetted part and nothing inside the vessel to clean. For food, pharmaceutical and chemical duty that is a substantial advantage.

What determines whether it will work:

  • Wall thickness and material. The wall consumes part of the sensing range. A thin polypropylene wall costs little; a thick glass-reinforced one may consume most of it.
  • The dielectric contrast between full and empty. Water against air is easy. Dry granulate against air is harder and needs care.
  • Whether product clings to the inside of the wall. If it does, the sensor reads full permanently. This is the single most common reason a through-wall installation fails, and it must be assessed before ordering rather than after.

Our note on capacitive proximity sensors for level detection goes into the level application in more depth.

Where capacitive switches earn their place

  • Packaging lines — detecting cartons, bottles, film and labels that inductive sensors cannot see.
  • Level in non-metallic vessels — high and low level switching without breaching the tank.
  • Powder and granulate handling — hoppers, silos, feed chutes and blocked-chute detection.
  • Plastics processing — presence of mouldings, sprue detection, bin-full signalling.
  • Timber and panel handling — board presence and edge detection.
  • Glass handling — where optical sensing is defeated by transparency.

The Accent capacitive range

Our capacitive proximity switches are M30 bodies with 10 mm sensing range, available across the full output matrix. The ordering code is straightforward once you know the pattern:

  • D32C-3010-NM-3S — NPN, normally open, 3-wire, 300 mA, short-circuit protected
  • D32C-3010-NB-3S — NPN, normally closed, short-circuit protected
  • D32C-3010-PM-3S — PNP, normally open, short-circuit protected
  • D32C-3010-PB-3S — PNP, normally closed, short-circuit protected

The same four are available without short-circuit protection as the -3 suffix rather than -3S. In almost every case the protected version is the right choice — the price difference is small and a shorted output on an unprotected sensor destroys it.

Reading the code: N or P selects NPN or PNP, M or B selects normally open (make) or normally closed (break), and 3S indicates 3-wire with short-circuit protection. If you are unsure whether your input card wants NPN or PNP, our guide to PNP and NPN sensors covers it.

Two mistakes worth avoiding

Setting the sensitivity at commissioning and never revisiting it. A capacitive sensor adjusted on a clean, dry morning will behave differently in humid weather and differently again with six months of product film on the face. Set it with margin, and specify a mounting position where the face can be wiped.

Mounting it where splash or condensation lands on the face. Water has a very high dielectric constant. A sensor that gets splashed will trigger on the splash. Shield it, angle it downward, or move it.

Specifying one

Tell us the target material, whether you are sensing it directly or through a wall, the wall material and thickness if so, the required sensing distance, whether the target is stationary or moving and how fast, the output your controller needs, and the environment — washdown, dust, temperature. If the target is a powder or granulate, the bulk density is worth including.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Hot Metal Detectors: What to Specify Before You Order

A hot metal detector is specified by geometry and timing, not by a catalogue number. The seven parameters that decide whether an HMD works on your mill, and the mistakes that cause false trips.

A hot metal detector looks like a simple device. It watches for the infrared signature of hot stock and gives a signal when it sees one. In practice HMD installations fail more often than almost anything else on a rolling mill, and they fail for reasons that are decided at specification, not at installation.

This guide sets out what actually needs to be established before ordering, based on the enquiries that come to us and the ones that come back six months later.

What the device is doing

Hot stock radiates. A hot metal detector is an infrared receiver aimed at a defined point in the pass line, with the sensitivity and optics arranged so that it responds to the radiation from the stock and ignores everything else in the mill.

Everything difficult about HMD selection follows from that second clause. A rolling mill is full of hot objects: adjacent stands, furnace doors left open, glowing scale on the floor, steam backlit by something hot, a neighbouring line. The specification problem is not detecting the bar. It is not detecting anything else.

1. Field of view and mounting distance

These two are a single decision, because field of view at the target is a function of the optical angle and the distance.

Mount too close and you lose tolerance — a bar that wanders laterally leaves the field and the detector drops out mid-pass. Mount too far and the field widens until it takes in the stand behind, and the detector never drops out at all because it can always see something hot.

Establish the actual mounting distance before selecting the device, and establish the lateral wander the pass line really has, not the nominal centre line. On a roughing mill that difference can be substantial.

2. The smallest target you must detect

Specify by the smallest and coolest stock the line runs, not the typical product. A detector configured around a 100 mm slab at full temperature will miss the tail end of a thin section that has cooled on a delay. The awkward end of the product range sets the requirement.

3. Response time against line speed

On a fast finishing mill the stock may be in the field of view for a very short time, and the detector output has to be present long enough for the PLC scan to catch it. Two separate things need checking: that the detector responds fast enough, and that the control system samples fast enough to see the response.

An HMD that works perfectly on the roughing side and misses intermittently on the finishing side is almost always this problem rather than a faulty device.

4. Temperature threshold

Too sensitive and the detector picks up residual heat, scale and radiated background. Too insensitive and it misses cooled tail ends. The threshold should be set from the coolest stock that must be detected, with margin, and then checked against the hottest background that must be ignored. If those two overlap, the geometry needs changing — no threshold setting will resolve it.

5. The environment the device has to survive

A rolling mill is a hostile place for electronics. Three things matter:

  • Ambient temperature at the mounting point. Not the mill ambient — the temperature where the device actually sits, which near a stand can be far higher.
  • Cooling and air purge. Most mill installations need cooling for the housing and a purge to keep the optical window clear. An air purge is not an optional extra; a dirty window is the most common cause of a detector that gradually stops working.
  • Water, scale and mechanical damage. Descaling spray, cobbles and maintenance traffic all reach places the designer assumed were protected.

Plan the purge air supply at the same time as the detector. Retrofitting it is expensive and frequently never happens.

6. Output and integration

Confirm what the control system expects — relay contact, transistor output, or an analogue signal — and the supply voltage available at the mounting point. On older mills the panel may have no DC supply where you need it, which changes the specification.

7. Alignment and maintenance access

The detector will need aligning during commissioning, and realigning after any mechanical work nearby. A device mounted where nobody can reach it safely with the line running will drift out of alignment and stay there. Specify the mounting bracket and access at the same time as the detector.

The three mistakes we see most often

Specifying from the catalogue instead of the geometry. The model number matters far less than field of view at the actual mounting distance.

No air purge. Works for three months, degrades slowly, gets blamed on the device.

Ignoring what else is hot. The single most common cause of false triggering, and the hardest to fix afterwards because it usually requires moving the mounting position.

Applications beyond rolling mills

Hot metal detectors are specified wherever hot stock has to be tracked without contact — continuous casting, forging lines, billet handling, furnace charging and discharge, shear control and cut-to-length. The specification logic is the same in each case: geometry first, timing second, environment third.

Getting a recommendation

Send us the mounting distance, the smallest and coolest stock to be detected, the line speed, what else is hot within the likely field of view, the ambient temperature at the mounting point, whether purge air is available, and the output your control system needs. A photograph or sketch of the intended mounting position is worth more than any of the individual numbers.

For background on how HMDs are used across a mill, see our overview of hot metal detectors in rolling mills.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Proximity Sensor Dealers in India: Buying Direct or Through a Channel

Dealer, distributor, authorised distributor and reseller are not synonyms. What each route is genuinely good for, when going direct is worth it, and how to spot grey-market stock before it reaches site.

Dealer, distributor, authorised distributor, channel partner, reseller. In Indian industrial supply these words get used interchangeably, and they describe very different commercial relationships. The distinction is invisible when everything works and extremely visible when something fails.

Here is what each route actually is, what it is good at, and how to tell which one you are dealing with.

The four routes, honestly described

Direct from the manufacturer. You buy from whoever built the product. Best technical depth, best access to variants, best position on a warranty claim. Usually the right route for volume, for anything non-standard, and for products that will be supported over a plant lifetime.

Authorised distributor. A contracted relationship with the manufacturer, carrying factory warranty and factory technical escalation. This is the standard route for imported product — it is how a German or Swiss manufacturer serves India without operating here directly. Accent holds this relationship for Novotechnik and Contelec across India and SAARC.

Stockist or dealer. Buys from distributors, holds inventory, sells locally. Genuinely valuable when you need something today and the alternative is a week. The trade-off is that technical support is thin and the range is whatever moves fastest.

Reseller or trader. Buys wherever the price is lowest, including from other markets. Sometimes a legitimate surplus channel. Sometimes grey-market product with no supported warranty route. The difficulty is that it looks identical to the other three on a website.

When going direct is worth the effort

Direct is not automatically better. It is better in specific situations:

  • Volume orders. Pricing improves, and production can be scheduled against your delivery dates rather than drawn from someone inventory.
  • Anything non-standard. A specific cable length, a different connector, a housing variant. Dealers cannot authorise these; manufacturers can quote them.
  • Difficult applications. When the sensing problem is genuinely hard, you want the person who understands the electronics, not the person who understands the catalogue.
  • Long-life plant. A direct relationship with a manufacturer survives longer than a dealer relationship, and matters when you need the same part in year eight.
  • Certification requirements. Documentation comes from the manufacturer. Going through intermediaries adds delay and loses papers.

When a local stockist is the right answer

When the line is down and the part is standard. A stockist two hours away with the right M18 PNP switch on the shelf beats a better price arriving Thursday. Buy the emergency locally, then fix the underlying spares holding afterwards.

How to spot grey-market stock

This is the practical risk in the Indian market, and it is worth knowing the signals.

  1. The price is well below everyone else. Distribution margins are not large. A price substantially below the market usually means the product came in through an unofficial route, or it is old stock, or it is not what the label says.
  2. The seller will not put authorised in writing. Ask directly. An authorised party confirms it immediately.
  3. They cannot produce a full ordering code. Series names are public. Configuration codes come from the manufacturer ordering system.
  4. The warranty is theirs, not the manufacturer. A seller-backed warranty on imported product is the clearest signal there is.
  5. No documentation, or documentation later. Declarations of conformity and test certificates should accompany the goods.
  6. Vague delivery. Authorised channels can tell you whether something is in stock in India, in stock at the factory, or on a production run. Traders often cannot, because they are sourcing it after you order.

What we do

Accent occupies both positions, which is unusual and worth being explicit about.

For inductive, capacitive, photoelectric, magnetic and NAMUR proximity switches, we are the manufacturer — built in Mumbai since 1985 to IEC 60947-5-2, with variants quoted on request.

For Novotechnik linear and rotary position sensors, and for Contelec, we are the sole authorised distributor for India and SAARC, carrying factory warranty and factory engineering escalation.

The practical benefit is that one enquiry can cover both. A machine that needs twelve proximity switches and two linear transducers does not need two suppliers, two purchase orders and two warranty routes. If you want to verify the distribution claim rather than take it on trust, our guide on checking authorised Novotechnik stock explains exactly how.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

Proximity Sensor Manufacturers in India: A Buyer’s Checklist

Most proximity sensor suppliers in India are importers or rebadgers rather than manufacturers. Eight checks that separate a manufacturer from a box-shifter, and why it matters in year three.

Search for proximity sensor manufacturers in India and you will get a long list. Most of the companies on it do not manufacture anything. They import, they rebadge, or they assemble from bought-in modules — all legitimate businesses, but not the same thing, and the difference matters once you need a variant, a certificate, or a replacement for a part you bought four years ago.

This is the checklist we would use ourselves. It is deliberately written so that it can be applied to Accent as easily as to anyone else.

1. Ask what standard the product is built to

For inductive and capacitive proximity switches, the relevant standard is IEC 60947-5-2. It defines sensing distance and its tolerances, the standard target, switching frequency, and the behaviour that makes one manufacturer sensing distance comparable with another.

A supplier who cannot name the standard their product is built to is telling you something. A supplier who quotes a sensing distance without specifying whether it is rated, effective or assured operating distance is telling you something more subtle but just as useful — those three numbers differ, and the gap between them is where field failures live.

Accent manufactures to IEC 60947-5-2. Ask us for the figures against that standard and we will give them to you.

2. Ask to see where it is made

Not a photograph of a building. Ask whether you can visit, and watch how the question is received. A manufacturer will treat a plant visit from a serious buyer as normal. An importer will find reasons.

Our factory is in Vikhroli, Mumbai, and has been producing sensors since 1985.

3. Ask whether they can make a variant

This is the fastest way to establish what a supplier really is. Ask for a non-standard cable length, a different connector, or a specific housing material. A manufacturer will quote it, with a lead time and a quantity threshold. A reseller will explain why the catalogue option is better for you.

Variant capability is not a luxury. On an OEM machine build, being able to specify the exact cable length removes junction boxes, cable management and installation labour from every unit you ship.

4. Ask what happens to a part number in five years

Industrial plant outlives industrial catalogues. The question that matters on a twenty year asset is whether the same part will still be available, or whether you will be in a cross-reference exercise trying to establish what replaces it.

Importers are exposed here in a way manufacturers are not — when the overseas principal rationalises a range or changes distributor, the Indian supplier loses the part regardless of what they promised you.

5. Ask about traceability

Can they tell you which production batch a given serial number came from? If you are supplying into automotive, pharmaceutical or export machinery, your own quality system probably requires component traceability, and discovering at audit that your sensor supplier cannot provide it is an unpleasant surprise.

6. Separate the sensing distance claim from the application

A headline sensing distance is measured against a standard mild steel target under standard conditions. Your target is probably not that. Stainless steel, aluminium, brass and copper all reduce the effective sensing distance, some of them substantially — the correction is real and predictable, and a manufacturer will apply it for you without being asked.

If a supplier quotes the catalogue distance for an aluminium target without mentioning the reduction factor, they have not understood the application. Our note on reduction factors for different metals covers the arithmetic.

7. Check the range covers the awkward cases

Every supplier stocks M18 and M30 DC three-wire PNP. The range is tested by the things you need occasionally:

A supplier who has only the easy part of the range will leave you sourcing the rest from three other vendors.

8. Ask who answers a technical question

Not the sales contact — the engineer. On a difficult application, the value of a supplier is concentrated in the twenty minutes someone spends working out why a sensor is chattering. If there is no one to ask, the catalogue was the whole product.

Where imported product still wins

An honest checklist needs this section. Imported product is the right answer when you need something genuinely specialist that is not made domestically — high-precision absolute position measurement being the obvious case. That is why we distribute Novotechnik alongside our own manufacturing rather than pretending an inductive switch can do a linear transducer job.

The useful question is not Indian or imported. It is whether your supplier is willing to tell you which one your application actually needs.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

NAMUR Proximity Switch Suppliers in India: Buying in Volume

Buying NAMUR switches in quantity is a different exercise from buying one. What actually drives the landed cost, why imported stock stalls projects, and what to ask a supplier before you commit a schedule to them.

Buying one NAMUR proximity switch is a catalogue exercise. Buying two hundred for a plant build, or committing to a call-off schedule for an OEM machine line, is a supply chain decision — and the things that matter change completely.

Accent Controls manufactures NAMUR inductive proximity switches in Mumbai. This page sets out what genuinely drives cost and delivery on volume orders, and the questions worth asking any supplier, including us.

Where the money actually goes

On a bulk NAMUR order, the unit price is rarely the largest variable. Three other factors usually move the landed cost more.

Customs duty and clearance on imported stock. A European NAMUR switch lands in India carrying duty, freight, clearance charges and an exchange rate you agreed weeks earlier. On a two hundred piece order those line items are not a rounding error. Domestically manufactured product removes them entirely, which is frequently a larger saving than any negotiation on unit price.

Minimum order quantities you did not want. Imported ranges are often stocked in Europe in pack sizes that suit European distribution. Needing 40 of an M18 8 mm and being quoted a box of 100 is a common and expensive outcome.

The cost of a stalled schedule. This is the one that hurts. If a plant build is waiting on a sensor delivery held at customs, the cost is not the sensor. It is the commissioning team standing idle and the liquidated damages clause in your contract.

Why the NAMUR range in particular causes delivery problems

NAMUR sensors are a specialist line. Distributors who stock general-purpose PNP and NPN inductive switches in depth frequently do not stock NAMUR variants at all, because turnover is lower. The sensor that was quoted from a catalogue in two days turns out to be on a six to eight week factory lead time.

The failure mode this produces is worse than a delay. Under schedule pressure, someone substitutes a standard three-wire sensor with a barrier and hopes it will pass. It will not — a conventional sensor cannot produce the diagnostic current band that makes NAMUR NAMUR, and the loop cannot be certified. The substitution gets discovered at inspection, and now you have a delay and a rework.

What manufacturing in India changes

Accent has built sensors in Mumbai since 1985, to IEC 60947-5-2. For a volume buyer that has a few practical consequences.

Lead time is a production question, not a shipping question. There is no ocean freight leg and no customs clearance in the critical path.

Quantities are what you asked for. Production runs are scheduled against the order rather than drawn from a European pack size.

Variants are possible. Cable length, connector type and housing details can be specified rather than accepted. On a large order this frequently removes an entire assembly operation at your end — a sensor supplied with the right cable length does not need a junction box.

A failure is a phone call. Warranty and technical support happen in the same time zone, in the same country, without a distributor relaying questions to a factory that answers overnight.

The standard range

Our NAMUR inductive proximity switches cover the thread sizes and sensing distances that account for the large majority of process plant requirements:

  • D20C-1204-NA — M12 body, 4 mm sensing
  • D20C-1805-NA — M18 body, 5 mm sensing
  • D20C-1808-NA — M18 body, 8 mm sensing
  • D20C-3010-NA — M30 body, 10 mm sensing
  • D20C-3015-NA — M30 body, 15 mm sensing

Pair them with our NAMUR control unit, which converts the sensor current signal into a relay output and indicates power, cable fault and relay status on the front panel. Ordering sensor and amplifier together is usually the right approach — see our guide to specifying intrinsically safe NAMUR loops.

Questions worth asking any NAMUR supplier

  1. Is this stock, or a factory lead time? Get the answer in weeks, in writing.
  2. What is the minimum order quantity per variant? Not per order — per variant. This is where quotations quietly inflate.
  3. Can cable length and connector be specified? If the answer is no, budget for the junction boxes.
  4. Who supplies the amplifier, and has this combination been used together?
  5. What certification documents come with the delivery, and when? Documents that arrive after the equipment are a common cause of inspection delays.
  6. What is the replacement route for a failure in year two? On a plant with a twenty year life, this outlasts most supplier relationships.

Getting a volume quotation

Send the quantity by variant, the required delivery schedule, whether you need a call-off arrangement, cable and connector requirements, and any certification the project specification demands. If you have a bill of materials, send it as it stands — we will mark up the equivalents rather than ask you to translate it first.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com

UL, CSA and Zone 0: Specifying Intrinsically Safe NAMUR Proximity Switches

Zone 0 does not permit an ordinary proximity switch, whatever its IP rating. What NAMUR actually standardises, how the barrier completes the safety case, and the approvals to confirm before you order.

Every few weeks we get an enquiry that reads roughly: we need an intrinsically safe NAMUR proximity switch, UL or CSA approved, suitable for Zone 0. It is a precise-sounding request that usually hides three separate decisions, and getting them confused is how projects end up with hardware that cannot be certified on site.

This guide separates them: what NAMUR actually is, what intrinsic safety requires beyond the sensor, and which approvals matter for which jurisdiction.

NAMUR is a signal standard, not a safety approval

This is the single most common misunderstanding. NAMUR — defined in IEC and EN 60947-5-6, and still occasionally called by its old designation DIN 19234 — specifies how a proximity switch communicates, not whether it is certified for a hazardous area.

A NAMUR sensor is a two-wire device with no output transistor. It does not switch a load. Instead it changes the current it draws from a nominal 8.2 V supply provided by an amplifier:

  • Target absent (undamped) — the sensor draws a higher current, typically above roughly 2.1 mA.
  • Target present (damped) — the sensor draws a lower current, typically below roughly 1.2 mA.

Because both normal states sit inside a defined, narrow band, anything outside that band is diagnostically meaningful. Near-zero current indicates a broken wire. Very high current indicates a short circuit. The amplifier can therefore distinguish a genuine fault from a legitimate sensor state — something a conventional three-wire PNP sensor simply cannot do, because its off state and a severed cable look identical.

That diagnostic capability is why NAMUR is used in process industries even outside hazardous areas. On a critical interlock, knowing that the sensor is healthy matters as much as knowing what it sees.

Why NAMUR and intrinsic safety go together

The second property of a NAMUR sensor is that it contains no energy storage of consequence and draws only milliamps. It is a simple apparatus in intrinsic safety terms. That makes it a natural building block for an intrinsically safe circuit, where the principle is to limit the electrical and thermal energy available in the hazardous area to below what can ignite the atmosphere present.

But the sensor alone does not create intrinsic safety. The loop does. An intrinsically safe installation is the sensor, the barrier or isolating amplifier, the cable, and the documented assessment that ties them together. Substituting any one element invalidates the case.

The barrier is not optional, and it is not an accessory

A NAMUR sensor cannot be wired directly to a PLC input. It needs an amplifier that supplies the 8.2 V, interprets the current, and presents a usable output to the control system. In a hazardous-area installation that amplifier also performs the energy limiting.

Our NAMUR control unit is built for exactly this arrangement: the sensor sits in the hazardous area and connects by two wires to the control unit, which is mounted in the safe area or inside a flameproof enclosure, and converts the low-current signal into a relay switching action. It works with inductive or capacitive NAMUR sensors, and carries three front-panel LEDs for power, cable fault and relay status — the cable fault indicator being the visible expression of the diagnostic band described above.

Specify the sensor and the amplifier together. Buying them separately from different sources is how loops end up unverifiable.

Zones, and why Zone 0 is a different conversation

Hazardous areas are classified by how often an explosive atmosphere is actually present:

  • Zone 0 — present continuously, or for long periods. Inside tanks and vessels, typically.
  • Zone 1 — likely to occur in normal operation.
  • Zone 2 — unlikely in normal operation, and short-lived if it occurs.

Zone 0 is the demanding case, and it is where specifications need to be exact rather than approximately right. Equipment for Zone 0 requires the highest protection level, and the assessment covers the whole loop rather than the sensor in isolation. If your application is genuinely Zone 0 — inside a solvent tank, for example, rather than in the bunded area around it — say so at the enquiry stage. The difference changes the hardware.

It is worth confirming the zone classification with whoever produced your area classification drawing before ordering. A surprising number of enquiries specify Zone 0 for locations that are correctly classified Zone 1, which widens the available options considerably.

UL, CSA, ATEX, IECEx: which one you need

Approval schemes are regional, and the right one depends on where the plant is and who is signing it off.

  • ATEX — the European scheme, and the one most often referenced in Indian project specifications because so much process plant is built to European standards.
  • IECEx — the international scheme, widely accepted and often the most practical route for equipment crossing borders.
  • UL and CSA — the North American schemes. These appear in Indian enquiries mainly where the end client, the licensor or the EPC contractor is American or Canadian, or where the plant is being built for export.

These are not interchangeable, and a certificate under one scheme does not automatically satisfy an inspector working to another. Establish which scheme your project actually requires before the technical bid evaluation, not after.

What to confirm before you order

  1. The zone, gas group and temperature class from your area classification document — not an estimate.
  2. Which approval scheme the project specification calls for, and who accepts it.
  3. Whether the certification must cover the loop or only the sensor. This determines whether the barrier must be bought as a matched pair.
  4. Sensing distance and target material, remembering that an inductive sensor sees non-ferrous metals at a reduced distance.
  5. The thread size and sensing range your mounting allows.
  6. Cable length and routing, because intrinsic safety calculations are affected by cable capacitance and inductance over long runs.

The Accent NAMUR range

We manufacture NAMUR inductive proximity switches in Mumbai in M12, M18 and M30 threads, with sensing distances from 4 mm to 15 mm:

  • D20C-1204-NA — M12, 4 mm
  • D20C-1805-NA — M18, 5 mm
  • D20C-1808-NA — M18, 8 mm
  • D20C-3010-NA — M30, 10 mm
  • D20C-3015-NA — M30, 15 mm

Because approval requirements vary so much by project and by jurisdiction, tell us which scheme and which zone your specification calls for when you enquire, and we will confirm exactly what we can supply against it and what the documentation package looks like. That is a better conversation to have before the purchase order than during commissioning.

For background on how NAMUR sensors behave electrically, see our explainer on NAMUR proximity sensors.

Need a price, a drawing or a stock check?

Send us the part number, or just describe the application and the target you need to sense. We will come back with the right model, a dimensional drawing and a quotation. Accent Controls has built sensors in Mumbai since 1985 and is the sole authorised distributor in India and SAARC for Novotechnik (Germany) and Contelec (Switzerland).

Request a quotation  ·  +91 98673 64004  ·  info@accentsensors.com